QP Advisory Pte Ltd +65 9800 4385 WhatsApp pe@qp.sg

Resources

ECM site inspection checklist

A practical checklist for inspecting Earth Control Measures (ECM) on Singapore construction sites, so that silt-laden water does not leave the site and enter public drains. Prepared by Er. David Zheng, PE (Civil) No. 4385 and QECP No. Q0278.

1. Plan and documents

  • Current ECM plan endorsed by the QECP is on site and matches the present stage of works.
  • Changes in site layout, excavation or phasing are reflected in an updated ECM plan.
  • Previous inspection records and rectification items are available and closed out.

2. Perimeter control

  • Silt fences and perimeter bunds are continuous, upright and properly embedded, with no gaps or undermining.
  • Hoarding bases are sealed where runoff could escape.
  • No exposed soil slopes towards the site boundary without protection.

3. Collection and treatment

  • Earth drains and cut-off drains are clear of silt and debris and lead to the treatment system.
  • Silt traps and sediment basins are desilted and have adequate remaining capacity.
  • Any treatment plant or dosing system is operating and maintained.

4. Discharge

  • Discharge is only through the approved discharge point(s).
  • Discharged water is clear; turbidity / total suspended solids are monitored against PUB's limit (TSS not exceeding 50 mg/L).
  • No direct pumping of muddy water into public drains or roadside drains.

5. Vehicles and access

  • Wash-down bay at each site exit is working, with water directed to treatment.
  • Public roads outside the site are free of mud and debris.

6. Exposed areas and stockpiles

  • Exposed earth surfaces are minimised, covered or turfed where works are not active.
  • Soil stockpiles are covered and kept away from drains.
  • Defects are recorded with photos, with responsible party and target date for rectification.

Need a QECP inspection?

We inspect against the approved ECM plan, record defects with clear rectification items, and verify close-out before removal. Email pe@qp.sg or WhatsApp +65 9800 4385. Always confirm current requirements against PUB's Code of Practice on Surface Water Drainage.

Book an inspection
WhatsApp